HYDRAFLOW Clamp-on ultrasonic flow / energy meter
Water flowThermal energyThe Hydraflow C is a compact clamp-on ultrasonic flow and BTU meter for DN15 to DN40 pipes, delivering ±1% accuracy with Modbus RS485 and 4 to 20 mA output and clamp-on installation that needs no pipe modification
- Clamp-on installation for DN15 to DN40 metal, PVC, PP or PVDF pipes — no cutting or shutdown
- ±1% accuracy via transit-time ultrasonic measurement with 0.5 s response and 0.1 m/s low-velocity cut-off
- 4 to 20 mA output and Modbus RS485 communication, with optional pulse output
- 256×128 LCD display and EEPROM memory backup
- IP65 enclosure, −10°C to 60°C ambient range, with reverse-polarity, surge and short-circuit protection
Overview
The Hydraflow C is a compact clamp-on ultrasonic flow and BTU meter for measuring water and other clean liquids in closed pipes from DN15 to DN40, making it well suited to residential and light commercial buildings, district cooling sub-metering and MEP retrofit work. Because the transducers clamp onto the outside of the pipe, you measure flow with no pipe cutting, no welds and no process shutdown.
Built on transit-time ultrasonic measurement, the Hydraflow C delivers ±1% accuracy with a 0.5-second response time and a low-velocity cut-off of 0.1 m/s for stable readings at light loads. The 256×128 LCD, 4 to 20 mA output and Modbus RS485 communication (with optional pulse output) let you read flow locally and feed it straight into a BMS or energy-management platform.
Powered from 10 to 24 V DC at under 3 W, the meter carries an IP65 enclosure and operates across an ambient range of −10°C to 60°C, with built-in reverse-polarity, surge and output short-circuit protection for reliable service in mechanical rooms and plant spaces.
Everything for specification & install
Specifications
Full technical data below. Refer to the datasheet for ordering codes and dimensional drawings.
Technical Data
| Pipe size (mm) | DN15 to DN40 |
| Pipe material | Metal, PVC, PP or PVDF rigid plastic pipe |
| Liquid type | Water/other liquid (Single liquid medium without solid particles or impurities) |
| Operating temperature | 0-75°C (No freezing on the surface) |
| Low velocity cut off value (m/s) | 0.1 |
| Display | 256*128, LCD |
| Response time (s) | 0.5 |
| Accuracy (%) | ±1 |
| Memory backup | EEPROM |
| Power and I/O connection | M12 type connector |
| Output (mA) | 4 to 20 |
| Communication | Modbus RS485 |
| Optional output | Pulse |
| Power supply (V) | 10 to 24 DC |
| Electric power (W) | < 3 |
| Protective circuit | Power reverse connection protection, power surge protection, output short circuit protection, output surge protection |
| Enclosure protection class | IP65 |
| Ambient temperature | -10°C to 60°C |
| Relative humidity (%) | 35 to 85 RH |
| Vibration resistance | 10 to 55Hz double amplitude 1.5 mm, 2 hours in each XYZ axis |
| Impact resistant | 100 m/s 16 ms pulse, 1000 times each for X, Y and Z axis |
| Main material | Aluminum, Industrial plastics |
| Cable length | 2m (standard), PT1000 sensor standard cable length up to 9m |
Flow Range
| Pipe Size (DN) | Upper flow value(l/min) |
| 15 | 60 |
| 20 | 100 |
| 25 | 200 |
| 32 | 300 |
| 40 | 400 |
Request a quote for the Hydraflow