Technical Data
Size & Process Connection | mm | Thread connection:DN4, 6, 10, 15, 20, 32, 40, 50, 65, 80, 100 Flange connection:DN15, 20, 32, 40, 50, 65, 80, 100, 125, 200 Tri-Clamp connection:DN4, 6, 10, 15, 20, 32, 40, 50, 65, 80, 100 |
Accuracy | - | ±0.5%, ±0.2% (Optional) |
Sensor Material | - | SS304, SS316L (Optional) |
Impeller | - | 2Cr13 |
Temperature | °C | Medium temperature : –20 to 80 High temperature version: -20 to 150 Ambient temperature: -20 to 60 |
Signal Output | - | Pulse, 4-20 mA, Alarm (optional) |
Digital Communication | - | RS485 MODBUS RTU, HART |
Power Supply | - | 24V DC/3.6V Lithium Battery |
Cable Entry | - | M20*1.5; 1/2"NPT |
Explosion-proof class | - | Ex d IIC T6 Gb |
Protection class | - | IP65; IP67 (Optional) |
Structure | - | Compact, Remote |
Cable length | m | 10m standard, other length optional |
Technical Data
Size | Standard Flow Range (m3 /h) | Extended Flow Range (m3 /h) | Standard Connection and Pressure | Optional Pressure |
---|---|---|---|---|
DN4 | 0.04-0.25 | 0.04-0.4 | Thread/6.3MPa | Upto 42MPa |
DN6 | 0.1-0.6 | 0.06-0.6 | Thread/6.3MPa | |
DN10 | 0.2-1.2 | 0.15-1.5 | Thread/6.3MPa | |
DN15 | 0.6-6 | 0.4-8 | Thread/6.3MPa Flange/4.0MPa |
|
DN20 | 0.8-8 | 0.45-9 | Thread/6.3MPa Flange/4.0MPa |
|
DN25 | 1-10 | 0.5-10 | Thread/6.3MPa Flange/4.0MPa |
|
DN32 | 1.5-15 | 0.75-15 | Thread/6.3MPa Flange/4.0MPa |
|
DN40 | 2-20 | 1-20 | Thread/6.3MPa Flange/4.0MPa |
|
DN50 | 4-40 | 2-40 | Thread/6.3MPa Flange/4.0MPa |
|
DN65 | 7-70 | 3.5-70 | Thread/1.6MPa Flange/1.6MPa |
|
DN80 | 10-100 | 5-100 | Thread/1.6MPa Flange/1.6MPa |
|
DN100 | 20-200 | 10-200 | Thread/1.6MPa Flange/1.6MPa |
|
DN125 | 25-250 | 12.5-250 | Flange/1.6MPa | |
DN150 | 30-300 | 15-300 | Flange/1.6MPa | |
DN200 | 80-800 | 40-800 | Flange/1.6MPa | |
DN250 | 120-1200 | 60-1200 | Flange/1.6MPa | |
DN300 | 150-1500 | 75-1500 | Flange/1.6MPa |