D014

  • Displays​
    flow rate, total and accumulated total.
  • Ambient temperature​
    -40°C to +80°C (-40°F to +176°F).
  • Aluminum DIN front panel​
    of 144 x 72mm (5.67" x 2.83") according DIN 43700 / IEC 61554.
Request A Quote

The D014 is a local, panel mount indicator / transmitter to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. Related to the acculmulated total, a scaled pulse is generated for re-transmitting the count on the display. 

Display  
Type High intensity reflective numeric and alphanumeric LCD, UV-resistant.
Dimensions 90 x 40mm (3.5" x 1.6").
Digits Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units.
Refresh rate User definable: fast, 1sec , 3sec, 15sec, 30sec, off
Option ZB Transflective LCD with bi-color LED-backlight; green / amber. Intensitiy and color selected trough the keyboard. Good readings in full sunlight and darkness. 
Ambient temperature  
Safe areas  -40°C to +80°C (-40°F to +176°F).
Power requirements  
Type PB Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years.
Type PD 24V AC/DC ± 10%. Power consumption max. 10 Watt.
Type PL  Input loop powered from sensor signal 4 - 20mA (requires type A).
Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt
Type PX  8 - 30V DC. Power consumption max. 0.3 Watt.
Type ZB 20 - 30V DC. Power consumption max. 1 Watt. With type PD / PM: internally powered.
Sensor excitation  
Type PB/PX 3V DC for pulse signals and 1.2V DC for coil pick-up.
Note This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reed-switches. 
Type PD / PM  for pulse signals: 1.2 / 3 / 8.2 / 12 / 24V DC For analog signals: 8.2 / 12 / 24V DC 8.2V DC, Iout max. 35mA @ 20°C. 12V DC, Iout max. 50mA @ 20°C. 24V DC, Iout max. 75mA @ 20°C. (this voltage can vary depending on the input supply voltage)
Type PD / PM Total consumption of sensor, active output OH and backlight may not exceed 75mA @ 24V DC @ 20°C.

The D-Series is a DIN-sized display and the better alternative for your existing, not waterproof, front panel mount indicators in extreme weather outdoor applications or e.g. in food industries where working environments are often cleaned with powerful water jets.
The D014 fits in flow measurement applications where re-transmission of the totalizer function is required.